Infinite Energy² manufacturer brochure — IE2C-5
Review the published model ratings, dimensions and installation requirements for the selected boiler.

RBI Infinite Energy² 500 shown. Other sizes can differ.
Commercial hydronic heating with primary/secondary piping; the IB version is the space-heating boiler. Ask HTS about boiler replacement, installation and service for your Toronto or GTA building.
Boiler Quotes For Toronto & GTA Buildings.
Send your boiler nameplate and project details. Equipment selection, supply, pricing and installation timing are confirmed in your quotation.
Infinite Energy² is a floor-standing condensing boiler range with stainless steel water-tube heat exchangers. Its premix burner and integrated sequencing controls support individual commercial heating loads and multi-boiler plants.
Select a model to include it in your enquiry.
IB base model names are explicitly printed in manufacturer written specifications. Input figures follow the February 2023 boiler IOM technical-data tables; the 199 and 1000 sizes conflict with older brochure/submittal figures, as noted per row. No ordering suffixes are inferred. MBH means thousands of BTU per hour. Input is fuel input, not delivered heating output.
| Model / Size Reference | Input (MBH) | Selection Notes |
|---|---|---|
| IB-199 | 199.5 | Technical table, IOM p.130: 199,500 BTU/h. Its model-description section instead says 199,000; current linked brochure/submittal says 200,000. Confirm the selected unit rating; 199 is the nominal size designation. Published size: IB-199. |
| IB-399 | 399 | 8:1 published turndown. Published size: IB-399. |
| IB-500 | 500 | 10:1 published turndown. Published size: IB-500. |
| IB-750 | 750 | 15:1 published turndown. Published size: IB-750. |
| IB-1000 | 999 | Technical table, IOM p.131: 999,000 BTU/h; current linked brochure/submittal says 1,000,000. Confirm selected serial range. 20:1 published turndown. Published size: IB-1000. |
Include the building address, existing boiler and burner nameplates, installation photos, service history and the reason for the proposed work. Share mechanical drawings or the required heating load if available. HTS can help define the assessment, replacement selection and installation scope.
Explore Boiler Repair & MaintenanceModel literature to help plan your boiler replacement or service enquiry.
Review the published model ratings, dimensions and installation requirements for the selected boiler.
Review the published model ratings, dimensions and installation requirements for the selected boiler.
Review the published model ratings, dimensions and installation requirements for the selected boiler.
RBI
FlexCore
Commercial hydronic heating; variable-volume, full-flow and primary/secondary systems.
RBI
Torus
Commercial hydronic heating; variable-volume, full-flow and primary/secondary layouts.
RBI
Encore
Light-commercial hydronic heating; variable-volume, full-flow and primary/secondary systems.
Send the existing equipment details, building address and project requirements. HTS can discuss a site assessment, the proposed boiler and the work required for removal, installation and commissioning.
No. Model references help identify a family or size. Confirm the full order code, fuel, heating duty, water temperatures, venting, connections, controls and installation requirements before selecting replacement equipment.
Contact HTS with your boiler model and building details. We’ll help you plan the next step.