Valiant-FT Series II heating submittal — 99-0507 Rev.02
Review the published model ratings, dimensions and installation requirements for the selected boiler.

Representative CAMUS Valiant-FT Series II boiler. Appearance varies by size and configuration.
Commercial hydronic space heating and staged building boiler plants. Ask HTS about boiler replacement, installation and service for your Toronto or GTA building.
Boiler Quotes For Toronto & GTA Buildings.
Send your boiler nameplate and project details. Equipment selection, supply, pricing and installation timing are confirmed in your quotation.
A condensing stainless steel firetube boiler in five commercial sizes for hydronic heating systems.
Select a model to include it in your enquiry.
Exact VA model codes and maximum inputs are taken from CAMUS submittal 99-0507 Rev.02. The document specifies 10:1 turndown on natural gas and 5:1 on propane; confirm fuel configuration with the supplier. MBH means thousands of BTU per hour. Input is fuel input, not delivered heating output.
| Model / Size Reference | Input (MBH) | Selection Notes |
|---|---|---|
| VA0400 | 400 | Hydronic heating; maximum input. Published size: VA0400. |
| VA0500 | 500 | Hydronic heating; maximum input. Published size: VA0500. |
| VA0600 | 600 | Hydronic heating; maximum input. Published size: VA0600. |
| VA0725 | 725 | Hydronic heating; maximum input. Published size: VA0725. |
| VA0850 | 850 | Hydronic heating; maximum input. Published size: VA0850. |
Include the building address, existing boiler and burner nameplates, installation photos, service history and the reason for the proposed work. Share mechanical drawings or the required heating load if available. HTS can help define the assessment, replacement selection and installation scope.
Explore Boiler Repair & MaintenanceModel literature to help plan your boiler replacement or service enquiry.
Review the published model ratings, dimensions and installation requirements for the selected boiler.
Review the published model ratings, dimensions and installation requirements for the selected boiler.
CAMUS
DynaFlame
Commercial building heating and dedicated hot-water plants, with application-specific versions.
CAMUS
Dynaforce
Central hydronic heating plants; separate DRW models provide dedicated hot-water service.
CAMUS
Avenger Series I & II
Large commercial heating and hot-water plants, including multifamily buildings.
Send the existing equipment details, building address and project requirements. HTS can discuss a site assessment, the proposed boiler and the work required for removal, installation and commissioning.
No. Model references help identify a family or size. Confirm the full order code, fuel, heating duty, water temperatures, venting, connections, controls and installation requirements before selecting replacement equipment.
Contact HTS with your boiler model and building details. We’ll help you plan the next step.