Book Service

Find Your Next Step.

Popular places to start

LAARS MagnaTherm FT commercial boiler — manufacturer product image

Representative LAARS MagnaTherm FT boiler. Appearance varies by size and configuration.

LAARS Commercial Boilers

LAARS MagnaTherm FT Commercial Boiler

Commercial hydronic heating and indirect domestic-hot-water systems. Ask HTS about boiler replacement, installation and service for your Toronto or GTA building.

Model / Family
MagnaTherm FT
Project
Condo and commercial building boiler replacement or service

Boiler Quotes For Toronto & GTA Buildings.

Send your boiler nameplate and project details. Equipment selection, supply, pricing and installation timing are confirmed in your quotation.

LAARS Boiler Systems

MagnaTherm FT Boiler Replacement Options

A vertical condensing firetube boiler combining stainless steel heat transfer with combustion monitoring and plant-level controls.

  • Stainless steel vertical firetube heat exchanger with CF-Tech tubes.
  • Tru Trac oxygen-trim combustion control.
  • Laars Linc controls with a cascade of up to eight boilers.
Published Model References

LAARS MagnaTherm FT Boiler Models

Select a model to include it in your enquiry.

Published boiler size designations are shown, with maximum inputs from submittal 1460C. Size 1000 has 15:1 turndown; sizes 1500–3000 have 20:1. Natural gas is specified in this submittal. Confirm voltage, venting and installed output during selection. MBH means thousands of BTU per hour. Input is fuel input, not delivered heating output.

Model / Size ReferenceInput (MBH)Selection Notes
CFH1000999.9Published size designation; hydronic boiler. Base identifier shown; final option suffixes vary. Published size: 1000.
CFH15001500Published size designation; hydronic boiler. Base identifier shown; final option suffixes vary. Published size: 1500.
CFH20001999.9Published size designation; hydronic boiler. Base identifier shown; final option suffixes vary. Published size: 2000.
CFH30003000Published size designation; hydronic boiler. Base identifier shown; final option suffixes vary. Published size: 3000.
Commercial Boiler Selection

What To Consider Before You Change Your LAARS Boiler?

  1. Review gas and electrical capacity, venting and the required pump flow.
  2. Account for equipment-pad and service-access requirements.
  3. Review building heating demand, supply and return temperatures, required flow and plant staging before choosing replacement capacity.
  4. Confirm the complete equipment order code, fuel, electrical supply, venting, piping, controls and service access.
  5. Include removal, planned service interruptions, commissioning and final equipment documentation in the installation scope.

What Should You Send For A Boiler Quote?

Include the building address, existing boiler and burner nameplates, installation photos, service history and the reason for the proposed work. Share mechanical drawings or the required heating load if available. HTS can help define the assessment, replacement selection and installation scope.

Explore Boiler Repair & Maintenance

Download LAARS BoilerTechnical Documents Here

Model literature to help plan your boiler replacement or service enquiry.

Manufacturer Literature

MagnaTherm FT brochure — 1449

Review the published model ratings, dimensions and installation requirements for the selected boiler.

PDF
Manufacturer Literature

MagnaTherm FT boiler submittal — 1460

Review the published model ratings, dimensions and installation requirements for the selected boiler.

PDF
Manufacturer Literature

MagnaTherm FT installation manual — 1462

Review the published model ratings, dimensions and installation requirements for the selected boiler.

PDF
Manufacturer Literature

1462, printed page 5, Model Nomenclature — model identification

Review the published model ratings, dimensions and installation requirements for the selected boiler.

PDF
Keep Exploring

More LAARS Boiler Options

View All Commercial Boilers
Toronto & GTA Building Boilers

Boiler Replacement & Service Questions

Can HTS Help With LAARS MagnaTherm FT Boiler Replacement?

Send the existing equipment details, building address and project requirements. HTS can discuss a site assessment, the proposed boiler and the work required for removal, installation and commissioning.

Does A Similar Model Number Confirm A Direct Replacement?

No. Model references help identify a family or size. Confirm the full order code, fuel, heating duty, water temperatures, venting, connections, controls and installation requirements before selecting replacement equipment.

Need A New Boiler For Your Building?

Contact HTS with your boiler model and building details. We’ll help you plan the next step.