Book Service

Find Your Next Step.

Popular places to start

LAARS MagnaTherm HTD commercial boiler — manufacturer product image

Representative LAARS MagnaTherm HTD boiler. Appearance varies by size and configuration.

LAARS Commercial Boilers

LAARS MagnaTherm HTD Commercial Boiler

Large commercial hydronic plants, with a separate volume-water-heater configuration. Ask HTS about boiler replacement, installation and service for your Toronto or GTA building.

Model / Family
MagnaTherm HTD
Project
Condo and commercial building boiler replacement or service

Boiler Quotes For Toronto & GTA Buildings.

Send your boiler nameplate and project details. Equipment selection, supply, pricing and installation timing are confirmed in your quotation.

LAARS Boiler Systems

MagnaTherm HTD Boiler Replacement Options

A high-turndown stainless steel condensing boiler family for larger central plants, with oxygen-trim combustion and variable-pump control.

  • 20:1 modulation across all six published sizes.
  • Tru Trac oxygen trim and Laars Linc touchscreen control.
  • Vari-Prime control for a variable-speed boiler pump.
Published Model References

LAARS MagnaTherm HTD Boiler Models

Select a model to include it in your enquiry.

The listed sizes refer to the MGH hydronic-boiler family. Maximum inputs follow boiler submittal 1425A; size labels 2000 and 2500 have rated inputs of 1999 and 2499 MBH. Specify the separate water-heater configuration for direct domestic-water service. MBH means thousands of BTU per hour. Input is fuel input, not delivered heating output.

Model / Size ReferenceInput (MBH)Selection Notes
MGH16001600Published MGH hydronic-boiler size designation. Base identifier shown; final option suffixes vary. Published size: 1600.
MGH20001999Published MGH hydronic-boiler size designation. Base identifier shown; final option suffixes vary. Published size: 2000.
MGH25002499Published MGH hydronic-boiler size designation. Base identifier shown; final option suffixes vary. Published size: 2500.
MGH30003000Published MGH hydronic-boiler size designation. Base identifier shown; final option suffixes vary. Published size: 3000.
MGH35003500Published MGH hydronic-boiler size designation. Base identifier shown; final option suffixes vary. Published size: 3500.
MGH40004000Published MGH hydronic-boiler size designation. Base identifier shown; final option suffixes vary. Published size: 4000.
Commercial Boiler Selection

What To Consider Before You Change Your LAARS Boiler?

  1. Review removal and access routes; the removable top section can help installation.
  2. Confirm system flow, electrical service and heating versus water-heater configuration.
  3. Review building heating demand, supply and return temperatures, required flow and plant staging before choosing replacement capacity.
  4. Confirm the complete equipment order code, fuel, electrical supply, venting, piping, controls and service access.
  5. Include removal, planned service interruptions, commissioning and final equipment documentation in the installation scope.

What Should You Send For A Boiler Quote?

Include the building address, existing boiler and burner nameplates, installation photos, service history and the reason for the proposed work. Share mechanical drawings or the required heating load if available. HTS can help define the assessment, replacement selection and installation scope.

Explore Boiler Repair & Maintenance

Download LAARS BoilerTechnical Documents Here

Model literature to help plan your boiler replacement or service enquiry.

Manufacturer Literature

MagnaTherm HTD brochure — 1433

Review the published model ratings, dimensions and installation requirements for the selected boiler.

PDF
Manufacturer Literature

MagnaTherm HTD boiler submittal — 1425

Review the published model ratings, dimensions and installation requirements for the selected boiler.

PDF
Manufacturer Literature

MagnaTherm HTD water-heater submittal — 2165

Review the published model ratings, dimensions and installation requirements for the selected boiler.

PDF
Manufacturer Literature

1422E, printed page 5, Model Nomenclature — model identification

Review the published model ratings, dimensions and installation requirements for the selected boiler.

PDF
Keep Exploring

More LAARS Boiler Options

View All Commercial Boilers
Toronto & GTA Building Boilers

Boiler Replacement & Service Questions

Can HTS Help With LAARS MagnaTherm HTD Boiler Replacement?

Send the existing equipment details, building address and project requirements. HTS can discuss a site assessment, the proposed boiler and the work required for removal, installation and commissioning.

Does A Similar Model Number Confirm A Direct Replacement?

No. Model references help identify a family or size. Confirm the full order code, fuel, heating duty, water temperatures, venting, connections, controls and installation requirements before selecting replacement equipment.

Need A New Boiler For Your Building?

Contact HTS with your boiler model and building details. We’ll help you plan the next step.