Book Service

Find Your Next Step.

Popular places to start

Lochinvar Crest with Hellcat commercial boiler — manufacturer product image

Representative Lochinvar Crest with Hellcat boiler. Appearance varies by size and configuration.

Lochinvar Commercial Boilers

Lochinvar Crest Hellcat Commercial Boiler

Commercial hydronic space heating and multi-boiler heating plants. Ask HTS about boiler replacement, installation and service for your Toronto or GTA building.

Model / Family
Crest with Hellcat
Project
Condo and commercial building boiler replacement or service

Boiler Quotes For Toronto & GTA Buildings.

Send your boiler nameplate and project details. Equipment selection, supply, pricing and installation timing are confirmed in your quotation.

Lochinvar Boiler Systems

Crest with Hellcat Boiler Replacement Options

A commercial condensing fire-tube boiler for larger hydronic heating plants, with an oxygen-sensing combustion system that adjusts operation as installation conditions change.

  • RealTime O2 Trim adjusts combustion using oxygen-sensor feedback.
  • 316L stainless-steel fire tubes; published thermal efficiency is 96.0–96.2%, depending on model.
  • Smart Touch control includes a 10-inch touchscreen, Con·X·Us remote connectivity and sequencing for up to eight boilers.
Published Model References

Lochinvar Crest with Hellcat Boiler Models

Select a model to include it in your enquiry.

Input values are maximum fuel input in MBH (1 MBH = 1,000 Btu/h), not heat output. Natural-gas base model identifiers are reproduced from the manufacturer brochure. The brochure directs changing the final N to L for LP gas; ordering options and control suffixes are not expanded here. MBH means thousands of BTU per hour. Input is fuel input, not delivered heating output.

Model / Size ReferenceInput (MBH)Selection Notes
FCB1000N999Natural-gas base model.
FCB1500N1500Natural-gas base model.
FCB2000N1999Natural-gas base model.
FCB2500N2500Natural-gas base model.
FCB3000N3000Natural-gas base model.
FCB4000N3999Natural-gas base model.
FCB5000N4999Natural-gas base model.
FCB6000N6000Natural-gas base model.
Commercial Boiler Selection

What To Consider Before You Change Your Lochinvar Boiler?

  1. Eight input sizes span 999–6,000 MBH. FCB1500 and FCB2000 provide 25:1 turndown; the other listed sizes provide 20:1.
  2. Treat this as a separate catalogue family from the original Crest: model codes, combustion controls and physical enclosures differ.
  3. Confirm project voltage and vent material by model; the brochure specifies stainless-steel venting for FCB5000–6000.
  4. Review building heating demand, supply and return temperatures, required flow and plant staging before choosing replacement capacity.
  5. Confirm the complete equipment order code, fuel, electrical supply, venting, piping, controls and service access.
  6. Include removal, planned service interruptions, commissioning and final equipment documentation in the installation scope.

What Should You Send For A Boiler Quote?

Include the building address, existing boiler and burner nameplates, installation photos, service history and the reason for the proposed work. Share mechanical drawings or the required heating load if available. HTS can help define the assessment, replacement selection and installation scope.

Explore Boiler Repair & Maintenance

Download Lochinvar BoilerTechnical Documents Here

Model literature to help plan your boiler replacement or service enquiry.

Manufacturer Literature

Crest with Hellcat sales brochure

Review the published model ratings, dimensions and installation requirements for the selected boiler.

PDF
Manufacturer Literature

Crest with Hellcat submittal

Review the published model ratings, dimensions and installation requirements for the selected boiler.

PDF
Keep Exploring

More Lochinvar Boiler Options

View All Commercial Boilers
Toronto & GTA Building Boilers

Boiler Replacement & Service Questions

Can HTS Help With Lochinvar Crest with Hellcat Boiler Replacement?

Send the existing equipment details, building address and project requirements. HTS can discuss a site assessment, the proposed boiler and the work required for removal, installation and commissioning.

Does A Similar Model Number Confirm A Direct Replacement?

No. Model references help identify a family or size. Confirm the full order code, fuel, heating duty, water temperatures, venting, connections, controls and installation requirements before selecting replacement equipment.

Need A New Boiler For Your Building?