Book Service

Find Your Next Step.

Popular places to start

Lochinvar FTXL commercial boiler — manufacturer product image

Representative Lochinvar FTXL boiler. Appearance varies by size and configuration.

Lochinvar Commercial Boilers

Lochinvar FTXL Commercial Boiler

Light commercial hydronic space heating and staged boiler installations. Ask HTS about boiler replacement, installation and service for your Toronto or GTA building.

Model / Family
FTXL
Project
Condo and commercial building boiler replacement or service

Boiler Quotes For Toronto & GTA Buildings.

Send your boiler nameplate and project details. Equipment selection, supply, pricing and installation timing are confirmed in your quotation.

Lochinvar Boiler Systems

FTXL Boiler Replacement Options

A compact commercial condensing fire-tube boiler for hydronic heating, offering six sizes and touchscreen control with remote monitoring.

  • Stainless-steel fire-tube heat exchanger with published thermal efficiency up to 98.3%.
  • Smart Touch control combines a 7-inch touchscreen, Con·X·Us remote connectivity and cascade sequencing.
  • The 399, 500 and 999 MBH models provide 10:1 turndown; 600, 725 and 850 MBH models provide 7:1.
Published Model References

Lochinvar FTXL Boiler Models

Select a model to include it in your enquiry.

Maximum input is in MBH. The current brochure and submittal show FTX400(N,L) through FTX1000(N,L), with N for natural gas and L for LP gas. Natural-gas base identifiers are listed; firing-control suffixes require project selection. MBH means thousands of BTU per hour. Input is fuel input, not delivered heating output.

Model / Size ReferenceInput (MBH)Selection Notes
FTX400N399Natural-gas base model.
FTX500N500Natural-gas base model.
FTX600N600Natural-gas base model.
FTX725N725Natural-gas base model.
FTX850N850Natural-gas base model.
FTX1000N999Natural-gas base model.
Commercial Boiler Selection

What To Consider Before You Change Your Lochinvar Boiler?

  1. Six input sizes span 399–999 MBH. Select the size using the required heating load and manufacturer flow limits.
  2. The FTX1000 model has a published maximum input of 999 MBH in the current product page, brochure and submittal.
  3. The 999 MBH model uses a larger cabinet and higher minimum flow than smaller FTXL models; verify the submittal before replacement planning.
  4. Review building heating demand, supply and return temperatures, required flow and plant staging before choosing replacement capacity.
  5. Confirm the complete equipment order code, fuel, electrical supply, venting, piping, controls and service access.
  6. Include removal, planned service interruptions, commissioning and final equipment documentation in the installation scope.

What Should You Send For A Boiler Quote?

Include the building address, existing boiler and burner nameplates, installation photos, service history and the reason for the proposed work. Share mechanical drawings or the required heating load if available. HTS can help define the assessment, replacement selection and installation scope.

Explore Boiler Repair & Maintenance

Download Lochinvar BoilerTechnical Documents Here

Model literature to help plan your boiler replacement or service enquiry.

Manufacturer Literature

FTXL commercial boiler sales brochure

Review the published model ratings, dimensions and installation requirements for the selected boiler.

PDF
Manufacturer Literature

FTXL commercial boiler submittal

Review the published model ratings, dimensions and installation requirements for the selected boiler.

PDF
Keep Exploring

More Lochinvar Boiler Options

View All Commercial Boilers
Toronto & GTA Building Boilers

Boiler Replacement & Service Questions

Can HTS Help With Lochinvar FTXL Boiler Replacement?

Send the existing equipment details, building address and project requirements. HTS can discuss a site assessment, the proposed boiler and the work required for removal, installation and commissioning.

Does A Similar Model Number Confirm A Direct Replacement?

No. Model references help identify a family or size. Confirm the full order code, fuel, heating duty, water temperatures, venting, connections, controls and installation requirements before selecting replacement equipment.

Need A New Boiler For Your Building?

Contact HTS with your boiler model and building details. We’ll help you plan the next step.