Book Service

Find Your Next Step.

Popular places to start

Lochinvar Copper-fin II commercial boiler — manufacturer product image

Representative Lochinvar Copper-fin II boiler. Appearance varies by size and configuration.

Lochinvar Commercial Boilers

Lochinvar Copper-fin II Commercial Boiler

Commercial hydronic heating systems designed for non-condensing boilers. Ask HTS about boiler replacement, installation and service for your Toronto or GTA building.

Model / Family
Copper-fin II
Project
Condo and commercial building boiler replacement or service

Boiler Quotes For Toronto & GTA Buildings.

Send your boiler nameplate and project details. Equipment selection, supply, pricing and installation timing are confirmed in your quotation.

Lochinvar Boiler Systems

Copper-fin II Boiler Replacement Options

A commercial non-condensing copper-finned boiler with proportional firing, a gasketless heat exchanger and built-in sequencing for multiple boilers.

  • Nine input sizes span 399–2,070 MBH with published 85% thermal efficiency.
  • Copper-finned heat exchanger uses a gasketless design.
  • Proportional firing reaches up to 4:1 turndown, with Smart System control sequencing up to eight boilers.
Published Model References

Lochinvar Copper-fin II Boiler Models

Select a model to include it in your enquiry.

Maximum input is in MBH. Natural-gas base identifiers are reproduced from the current linked brochure and submittal. The manufacturer instructs changing N to L for LP gas; firing-control suffixes are configuration choices and are not generated here. MBH means thousands of BTU per hour. Input is fuel input, not delivered heating output.

Model / Size ReferenceInput (MBH)Selection Notes
CHN0402399Natural-gas base model.
CHN0502500Natural-gas base model.
CHN0652650Natural-gas base model.
CHN0752750Natural-gas base model.
CHN0992990Natural-gas base model.
CHN12621260Natural-gas base model.
CHN14421440Natural-gas base model.
CHN18021800Natural-gas base model.
CHN20722070Natural-gas base model.
Commercial Boiler Selection

What To Consider Before You Change Your Lochinvar Boiler?

  1. Confirm the exact model input: CHN0402 is 399 MBH, CHN0992 is 990 MBH and CHN2072 is 2,070 MBH.
  2. The smaller CH0402–0752 and larger CH0992–2072 groups differ in dimensions and water connections.
  3. Select venting, return-water temperature protection and firing controls using the project-specific manufacturer documents.
  4. Review building heating demand, supply and return temperatures, required flow and plant staging before choosing replacement capacity.
  5. Confirm the complete equipment order code, fuel, electrical supply, venting, piping, controls and service access.
  6. Include removal, planned service interruptions, commissioning and final equipment documentation in the installation scope.

What Should You Send For A Boiler Quote?

Include the building address, existing boiler and burner nameplates, installation photos, service history and the reason for the proposed work. Share mechanical drawings or the required heating load if available. HTS can help define the assessment, replacement selection and installation scope.

Explore Boiler Repair & Maintenance

Download Lochinvar BoilerTechnical Documents Here

Model literature to help plan your boiler replacement or service enquiry.

Manufacturer Literature

Copper-fin II commercial gas boiler sales brochure

Review the published model ratings, dimensions and installation requirements for the selected boiler.

PDF
Manufacturer Literature

Copper-fin II CH0402–2072 submittal

Review the published model ratings, dimensions and installation requirements for the selected boiler.

PDF
Keep Exploring

More Lochinvar Boiler Options

View All Commercial Boilers
Toronto & GTA Building Boilers

Boiler Replacement & Service Questions

Can HTS Help With Lochinvar Copper-fin II Boiler Replacement?

Send the existing equipment details, building address and project requirements. HTS can discuss a site assessment, the proposed boiler and the work required for removal, installation and commissioning.

Does A Similar Model Number Confirm A Direct Replacement?

No. Model references help identify a family or size. Confirm the full order code, fuel, heating duty, water temperatures, venting, connections, controls and installation requirements before selecting replacement equipment.

Need A New Boiler For Your Building?

Contact HTS with your boiler model and building details. We’ll help you plan the next step.